Call-connection service · Not affiliated with Stanford University · Repairs done by independent local technicians

StanfordAppliance Repair Specialists
Speak with a technician(000) 000-0000
(000) 000-0000

Service · Dryers

Dryer repair

When a dryer stops heating or takes two cycles, the cause is usually a restricted vent, a blown thermal fuse or a failed heating part. This line connects you with an independent technician who repairs gas and electric dryers around Stanford.

Call (000) 000-0000

Gas or electric: what tends to fail

  • Electric, drum turns, no heat: heating element, thermal fuse, high-limit thermostat, or half of the 240-volt breaker tripped.
  • Gas, igniter glows, no flame: worn gas valve coils, the most common gas dryer repair.
  • Will not start: door switch, thermal fuse, broken belt, start switch or motor.
  • Squealing or thumping: drum rollers, idler pulley or worn drum glides.
  • Very long cycles: a lint-choked vent, or moisture sensors coated with softener residue.

Look at the vent first

A blocked vent causes more dryer calls than any part. Empty the lint screen, then check the flexible duct behind the dryer for kinks. Outside, with the dryer running, the flap on the vent hood should open and push out warm air. Older Palo Alto and Menlo Park houses often had laundry added later, with long duct runs through crawl spaces or attics that collect lint for years.

If a thermal fuse has blown, a vent problem is the usual reason. Replacing the fuse without fixing the vent means it will blow again.

Safety

For gas dryers in Palo Alto, gas comes from Palo Alto Utilities; in Menlo Park, Atherton and on campus it is PG&E. If you smell gas, leave the building and call the utility or 911 from outside. Do not run a dryer that smells of burning or trips the breaker repeatedly.

Frequently asked

Why is my dryer running but not heating?

On electric models, start with both halves of the 240-volt breaker, then suspect the heating element or the thermal fuse. On gas models, an igniter that glows without lighting usually means the gas valve coils have failed. A blown fuse often points to a restricted vent, so check the airflow at the outside hood too. Tell the technician whether the dryer is gas or electric.

Why does my dryer stop after a few minutes?

It may be overheating because of a blocked vent, or a failing motor or thermostat may be cutting it out. Check the vent airflow first: with the dryer running, the outside flap should open and push warm air. Older Palo Alto and Menlo Park houses often have long duct runs through crawl spaces or attics. If airflow is strong, mention how long it runs before stopping.

Can I replace a thermal fuse myself?

You can, with the dryer unplugged or switched off at the breaker, but a thermal fuse blows for a reason. Find and clear the vent restriction first, or the new fuse will fail too. Check the flexible duct behind the dryer for kinks and the outside hood for lint. If the fuse keeps blowing with a clear vent, a thermostat or heating part needs testing by a technician.

Locations for this service

Stanford · Palo Alto · Menlo Park · Atherton

Other repairs: Refrigerator repair · Washer repair · Dishwasher repair · Range, oven and cooktop repair

Dryer not drying?

Call and say whether it is gas or electric, and what it is doing.

Call (000) 000-0000
Call (000) 000-0000